3.2 Nominal data
Motor M8D110-GF
Phase 3~ 3~ 3~ 3~
Nominal voltage / VAC 400 400 400 400
Connection Δ Y Δ Y
Frequency / Hz 50 50 60 60
Type of data definition ml ml ml ml
Valid for approval /
standard
CE CE CE CE
Speed / min
-1
660 520 725 460
Power input / W 330 190 430 210
Current draw / A 0.83 0.39 0.90 0.44
Max. back pressure / Pa 60 36 70 30
Min. ambient temperature
/ °C
-40 -40 -40 -40
Max. ambient
temperature
/ °C
65 65 55 55
Starting current / A 1.85 0.62 1.65 0.55
Maximum safe operating
speed / min
-1
1140
@ 70 °C
1140
@ 70 °C
1140
@ 70 °C
1140
@ 70 °C
Phase 3~ 3~
Nominal voltage / VAC 480 480
Connection Δ Y
Frequency / Hz 60 60
Type of data definition ml ml
Valid for approval /
standard
CE CE
Speed / min
-1
780 560
Power input / W 490 270
Current draw / A 0.94 0.45
Max. back pressure / Pa 80 37
Min. ambient temperature
/ °C
-40 -40
Max. ambient
temperature
/ °C
55 55
Starting current / A
Maximum safe operating
speed / min
-1
1140
@ 70 °C
1140
@ 70 °C
ml = Max. load · me = Max. efficiency · fa = Running at free air
cs = Customer specs · cu = Customer unit
Subject to alterations
3.3 Data according to ErP directive
Installation category A
Efficiency category Static
Variable speed drive No
Specific ratio
*
1.00
*
Specific ratio = 1 + pfs / 100 000 Pa
Actual Request
2013
Request
2015
Overall efficiency ηes / % 26.5 26.5 30.5
Efficiency grade N 36 36 40
Power input Pe / kW 0.32
Air flow qv / m³/h 5255
Pressure increase total psf / Pa 58
Speed n / min
-1
670
Data definition with optimum efficiency.
The ErP data is determined using a motor-impeller combination in a standardised
measurement configuration.
3.4 Technical features
Mass 10.1 kg
Size 630 mm
Surface of rotor Coated in black
Material of terminal box PP plastic
Material of blades Press-fitted sheet steel blank, sprayed
with PP plastic
Number of blades 5
Direction of air flow "V"
Type of protection IP 54
Insulation class "F"
Humidity class F4-1
Mounting position Shaft horizontal or rotor on bottom; rotor
on top on request
Condensate discharge
holes
Rotor-side
Operation mode S1
Motor bearing Ball bearing
Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)
<= 3.5 mA
Electrical leads Via terminal box
Motor protection Thermal overload protector (TOP)
brought out
Cable exit Axial
Protection class I (if protective earth is connected by
customer)
Product conforming
to standard
EN 61800-5-1; CE
Approval CCC; EAC; VDE
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
3.5 Mounting data
; Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
mounting screws
8.8
You can obtain additional mounting data from the product drawing if
necessary.