G2E085-AA01-01
Translation of the original operating instructions
3.2 Nominal data
Motor M2E042-CA
Phase 1~ 1~
Nominal voltage / VAC 230 230
Frequency / Hz 50 60
Type of data definition fa fa
Valid for approval /
standard
CE CE
Speed / min
-1
2350 2800
Power input / W 32 30
Current draw / A 0.15 0.14
Motor capacitor / µF 1 1
Capacitor voltage / VDB 400 400
Capacitor standard P2 (CE) P2 (CE)
Min. back pressure / Pa 0 0
Min. ambient temperature
/ °C
-25 -25
Max. ambient
temperature
/ °C
50 70
Starting current / A 0.2 0.2
ml = Max. load · me = Max. efficiency · fa = Running at free air
cs = Customer specs · cu = Customer unit
Subject to alterations
3.3 Technical features
Mass 0.85 kg
Size 85 mm
Surface of rotor Partially cast in aluminium
Material of impeller Sheet steel, hot-galvanised
Housing material Die-cast aluminium
Direction of rotation Clockwise, seen on rotor
Type of protection IP 44; Depending on installation and
position
Insulation class "B"
Mounting position Any
Condensate discharge
holes
None
Operation mode S1
Motor bearing Ball bearing
Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)
< 0.75 mA
Motor protection Thermal overload protector (TOP) wired
internally
Protection class I (if protective earth is connected by
customer)
Product conforming
to standard
EN 60335-1; CE
Approval CCC; EAC
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
3.4 Mounting data
For depth of screw, see chapter 3.1 Product drawing
; Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
mounting screws
8.8
You can obtain additional mounting data from the product drawing if
necessary.
3.5 Transport and storage conditions
; Use the device in accordance with its protection type.
Max. permissible
ambient motor temp.
(transp./ storage)
+ 80 °C
Min. permissible
ambient motor temp.
(transp./storage)
- 40 °C
Item no. 11064-5-9970 · Revision 82552 · Release 2014-05-08 · Page 5 / 9